◆Display a Hexadecimal Number with Tera Term You can also check if the binary is transmitted normally by the following hexadecimal display function.
TERA TERM WINDOWS 10 SERIAL
If it does not properly work, review the serial port settings and settings. Set the speed to 1 radian/second, rotate forward for 10 seconds, rotate backwards for 10 seconds, and stop. ( line is a comment statement) KeiganMotor KM-1 Teraterm Macro Demo Motor Operation: 10 Sec Forward → 10 Sec Reverse → Stopįor details on macros, see the following. ■km-1_teraterm_demo_1.zip Motor Speed: 1radian/second Please download the following and check the operation. There are prepared samples that are useful when operating with KeiganMotor. The macro function can be read and executed by selecting > in the upper right.
When sending a binary (byte string) to TeraTerm, the macro function is used because it takes a lot of time and effort manually. ※You can also search for solutions from the Support tab at the bottom right of the page. 【3】If the above problem can not be resolved There is a summarized workaround in a separate article.
TERA TERM WINDOWS 10 WINDOWS 10
【2】If you can not connect via USB in Windows 7 or Windows 10
TERA TERM WINDOWS 10 HOW TO
Please update the firmware of KeiganMotor to the latest version.ĭetails on how to update are described here. ◆Preparation for KeiganMotor and Tera TermĬlick here for a detailed connection method. Set the pull-down menu to 《Receive Binary》 Select from in the top menu 《Send Binary》 Select from in the top menu In order to send binary, please set according to the following flow. 《Baud Rate and Flow Control Settings》 Baud Rate (B): 115200įlow Control (F): hardware 2. Next, set the baud rate (B) and flow control (F) as follows. If you have KeiganMotor connected, select the USB port you are connecting to. ※以In the figure below, Port(P) COM6 is selected Select the USB port connected to the target. Serial Port Settingsįirst, set the serial port before serial transmission and serial reception. ◆Tera Term Environment SettingsĪfter starting the application, first set up the TeraTerm environment.Īfter that, it will be a setting assuming connection with the KeiganMotor, so you can freely change the following settings according to your purpose. Īfter jumping to the OSDN page, refer to the following to download the latest version.Īfter downloading, launch the application and proceed to the environment settings below. ・ TechShare(Physical Computing Lab) ◆Tera Term DownloadĪccess the Official Page (Tera Term Home Page) and click. 《Information About Our Product KeiganMotor》 【Product Site】 Some of the settings below can be used for other than the KeiganMotor, so please refer to them. In this page, we will explain how to control the KeiganMotorby linking TeraTerm with USB serial communication.